ECS EX5000

A high density, hot disk-swappable, object storage system, the EX5000 packs up to 11.2PB per rack and can grow into exabyte-scale with ease. It’s an ideal platform for long-term retention, storage consolidation and multipurpose object storage requirements that span S3, HDFS and archive workloads.

Категория: Метка:

Описание

h13117-emc-ecs-appliance-ss (1)
Node architecture
■ Intel x86 servers
■ Integrated storage
■ Up to 100 disk drives per node
Network connectivity
■ 25GbE FrontEnd
■ 25GbE BackEnd
Rack configurations
■ EX5000S: 1, through 7 node configurations (5 node minimum initial rack)
■ EX5000D: 2, through 14 node configurations (8 node minimum initial rack)
■ HA power
Storage configurations ■ Unstructured storage up to 11,200TB per rack
Architecture
■ Titan S standard 42U cabinet
■ EX5000S: 5U chassis containing server and disks
■ EX5000D: 5U chassis containing server and disks
■ Fully accessible – field serviceable components
■ Conventional front to back cooling
■ HA power cabling and cooling
Min / max cluster size
■ Single: 5 node minimum
■ No maximum
■ Dual: 8 node minimum
■ No maximum
Min / max rack configuration
Single:
■ Min: 1 chassis = 1 server with included disks
■ Max: 7 chassis = 7 servers with included disks Dual:
■ Min: 1 chassis = 1 server with included disks
■ Max: 7 chassis = 7 servers with included disks (14 nodes per 42U rack)
Node:disk ratios
■ EX5000S: 1:25, 1:50, 1:75, 1:100
■ EX5000D: 1:25, 1:50
Disk type (7200rpm, SATA) ■ 16TB
Raw capacity (per node) ■ 1600TB
Max raw capacity (per rack) ■ Up to 11,200TB
Node dimensions
■ 5U x D (970.4 mm) with CMA
■ Weight(maximum): 276lbs
Rack dimensions
■ H(78.4”) x W(23.6“) x D(47.2“) — including the front door
■ Weight: 1179kg/2600lb with 4 switches, 7 5U nodes
Max power ■ 2.4 kVA per 5U chassis
Max heatload ■ 8344 BTU/Hr for every 5U chassis
Power specifications (server) ■ 2x2400W power supplies per node(HA)
Power specifications (rack)
■ Connection: 8 single phase L6-30 (redundant power)
■ 30A circuit breaker (A) max. per AC power source
■ 2 three-phase WYE S52.30 (redundant power)
■ 32A circuit breaker (A) max. per AC power source
■ 2 three-phase delta CS-8365C (redundant power)
■ 50A circuit breaker (A) max. per AC power source
■ Input voltage (VAC): 200-240
■ Frequency (Hz): 50 — 60